Based on using carbon steel pipe (A53-GR B) filled with water
Spans are based on insulated and uninsulated lines below 650 Deg. F
     
 
 
 
 
           
           
             
             
             
Nom.   Wall Alowable      
Pipe Pipe Thickness Span Deflection    
Size Sch. Inches Ft- In (mm) Inches (mm) Ft- In (mm) Ft- In (mm)
3/4" 80 0,154 10'-0" (3048) 3/8" (10) 7'-0" (2134) 8'-0" (2438)
1" 80 0,179 13'-0" (3962) 1/2" (13) 9'-0" (2743) 10'-0" (3048)
1-1/2" 80 0,200 17'-0" (5182) 3/4" (19) 11'-0" (3353) 13'-0" (3962)
2" 40 0,154 19'-0" (5791) 1" (25) 12'-0" (3658) 14'-0" (4267)
2" 80 0,218 20'-0" (6096) 1" (25) 13'-0" (3962) 15'-0" (4572)
3" 40 0,216 25'-0" (7620) 1" (25) 16'-0" (4877) 18'-0" (5486)
4" 40 0,237 27'-0" (8230) 1" (25) 18'-0" (5486) 20'-0" (6096)
6" 40 0,280 33'-0" (10058) 1" (25) 22'-0" (6706) 25'-0" (7620)
8" 30 0,277 36'-0" (10973) 1" (25) 24'-0" (7315) 27'-0" (8230)
10" 20 0,250 38'-0" (11582) 1" (25) 25'-0" (7620) 29'-0" (8839)
10" 40 0,365 41'-0" (12497) 1" (25) 27'-0" (8230) 31'-0" (9449)
12" 20 0,250 40'-0" (12192) 1" (25) 26'-0" (7925) 30'-0" (9144)
12" Std 0,375 44'-0" (13411) 1" (25) 29'-0" (8839) 33'-0" (10058)
14" 10 0,250 42'-0" (12802) 1" (25) 27'-0" (8230) 31'-0" (9449)
14" Std 0,375 46'-0" (14021) 1" (25) 30'-0" (9144) 34'-0" (10363)
16" 10 0,250 44'-0" (13411) 1" (25) 28'-0" (8534) 33'-0" (10058)
16" Std 0,375 48'-0" (14630) 1" (25) 31'-0" (9449) 36'-0" (10973)
18" 10 0,250 45'-0" (13716) 1" (25) 29'-0" (8839) 34'-0" (10363)
18" Std 0,375 50'-0" (15240) 1" (25) 33'-0" (10058) 38'-0" (11582)
20" 10 0,250 47'-0" (14326) 1" (25) 31'-0" (9449) 36'-0" (10973)
20" 20 0,375 52'-0" (15850) 1" (25) 34'-0" (10363) 39'-0" (11887)
24" 10 0,250 49'-0" (14935) 1" (25) 32'-0" (9754) 37'-0" (11278)
24" 20 0,375 55'-0" (16764) 1" (25) 36'-0" (10973) 41'-0" (12497)